Extension | ■ | Ringing voltage: +5VDC, |
Jack |
| On a PARTNER Plus 220V System: +5VDC, |
Specifications | ■ 35- to | |
| ■ Ringing frequency: 20 Hz | |
|
| |
PAGE Jack | ■ Draws current on inner wire pair | |
Specifications | ■ Provides contact closure on outer wire pair | |
| ■ 600 Ohm impedance | |
|
| |
SMDR Output | ■ 1200 baud | |
Format | ■ No parity | |
| ■ 8 data bits | |
| ■ 2 stop bits | |
|
| |
Environmental | ■ Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required) | |
Requirements— | ■ Locate within 5 feet (1.5 meters) of the network interface jacks and an electrical outlet not | |
Control Unit |
| controlled by a switch, using supplied |
| ■ Operating temperature 32° to +104°F (0° to +40°C), not in direct sunlight | |
| ■ Humidity | |
| ■ For proper ventilation and easy replacement of modules, provide at least 6" (15.2cm) clearance | |
|
| at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit. |
| ■ Locate in an area free of excess moisture, corrosive gases, dust, and chemicals | |
|
| |
Electrical | ■ | |
Requirements |
| On a PARTNER Plus 220V System: |
| ■ Outlet must not be controlled by an on/off switch | |
| ■ Grounding to comply with Underwriters Laboratories (UL) 1459: | |
| A. An insulated grounding conductor that is not smaller in size and equivalent in insulation | |
|
| material and thickness to the grounded and ungrounded branch circuit supply conductors, |
|
| except that it is green with or without one or more yellow stripes, is to be installed as part of the |
|
| circuit that supplies the product or system. |
| B. The grounding conductor mentioned in item A is to be connected to ground at the service | |
|
| equipment. |
| C. The | |
|
| grounding type, and the grounding conductors serving these receptacles are to be connected |
|
| to earth ground at the service equipment. |
|
| |
Requirements for | Installation of a telephone or other standard (tip/ring) device in another building requires the | |
| following | |
Extensions | electrical surges: | |
| ■ System phone: two AT&T IROB protectors | |
| ■ Standard device: one AT&T IROB protector plus one carbon block protection | |
|
| |
Wiring | ■ System phones: AT&T SYSTIMAX® Bulk Nonplenum (DIW) cable, AT&T SYSTIMAX Bulk | |
|
| Plenum (HALAR/HALAR) cable, or at least |
■ Other standard telecommunications equipment
■ Bridging adapter: AT&T 267F2
■ Range: 1,000 feet (305 meters) for system phones: 3,000 feet (915 meters) for standard devices
22Specifications