| 6 - Technical specification | |
|
|
|
|
|
Features |
| Description |
|
|
(at 25°C enviromental temp.) |
|
|
| |
|
|
|
| |
|
| Ramp up and down | 0.1…999.9 digit/min (Off = 0) |
|
Setpoint |
| Low limit | From low range to the high limit |
|
|
| High limit | From low limit to the high range | |
|
|
|
|
|
OP4 PV retransmission |
| Galvanic isolation: 500 V~/1 min | Current output: 0/4…20mA 750Ω/15V max | |
| Resolution 12bit (0.025%) | |||
(option) |
| |||
| Accuracy: 0.1 % |
|
| |
|
|
|
| |
One shot |
| The controller selects automatically the best | Step response |
|
with automatic selection |
| method according to the process conditions | Natural frequency |
|
Serial comm. (option) | RS485 isolated, Modbus/Jbus protocol, 1200, 2400, 4800, 9600 bit/sec 2 wires | ||
Auxiliary Supply | +18V– ±20%, 30mA max | for an external transmitter supply | |
| Measure input |
| Detection of out of range, short circuit or sensor break with automatic |
|
| activation of the safety strategies and alerts on display | |
|
|
| |
Operational safety |
|
|
|
Control output |
| Safety value: 0…+100%. (user enabled/disabled) | |
| Parameters |
| parameter and configuration data are stored in a non volatile memory for |
|
| an unlimited time | |
|
|
| |
| Access protection |
| Password to access the configuration and parameters data |
|
|
| 100 - 240V~ (- 15% + 10%) 50/60Hz |
| Power supply |
| or 24V~ (- 25% + 12%) 50/60Hz and 24V– (- 15% + 25%) |
|
|
| Power consumption 1.6W max |
| Electric safety |
| Compliance to EN61010, installation class 2 (2500V) pollution class 2 |
General | Electromagnetic |
| Compliance to the CE standards for industrial system and equipment |
characteristics | compatibility |
| |
|
| ||
| Approvals |
| UL, cUL |
| Protection EN650529 |
| IP20 termination unit |
|
| IP65 front panel | |
|
|
| |
| Dimensions |
| 1/32 DIN - 48 x 24, depth 120 mm, weight 100 gr. apx. |
31