Atlona AT-PRO2HD1616M RS-232, Connection, Command, atlona.com, Function, Not used, Feedback

Models: AT-PRO2HD1616M

1 17
Download 17 pages 48.27 Kb
Page 11
Image 11
RS-232

RS-232

Connection

RS-232 is connected through a 9-pin female D connector. The pins will have functions associated with them, some will be unassigned.

5 ConnectionFunction 4 Not usedCommand3 FeedbackDescription2 Manual backgroundManual background 1

9 Manual backgroundManual background8 Manual backgroundManual background 7 Manual backgroundManual background 6

No.

1

2

3

4

5

6

7

8

9

Pin

Function

----

Not used

Tx

Transmit

Rx

Receive

----

Not used

Gnd

Ground

----

Not used

----

Not used

----

Not used

----

Not used

Command

The command codes are very sensitive, do not change capitalization, spacing, or lettering.

 

 

 

 

 

 

Command

Feedback
Description

 

 

 

 

 

 

 

PWON

PWON

Power on

 

 

PWOFF

PWOFF

Power off

 

 

All#

All#

Resets all inputs to corresponding outputs (input 3 to output 3)

 

 

x1$

x1$

Turns off output channel (to turn off output 3 = x3$)

 

 

x1AVx2

x1AVx2

Switch input to output (input 3 to output 5 = x3AVx5)

 

 

x1AVx2,x3,x4

x1AVx2,x3,x4

Switch input to multiple outputs (input 3 = x3AVx1,x2)

 

 

RS232zoneX[command]

RS232zoneX[command]

Send commands to devices connected to the receiver RS-232 ports.

 

 

 

 

Commands are the same as the ones stated in this table.

 

 

 

 

X = zone number

 

 

ex: RS232zone1[PWON]

ex: RS232zone1[PWON]

example: Turning the power on for the device connected in zone 1

 

 

Statusx1

x7AVx1

Shows what input is connected to selected output

 

 

Status

x1AVx1, x2AVx2,

Displays which inputs are currently connected to which outputs

 

 

 

x3AVx4, ....

 

 

 

SaveY (ex. Save2)

SaveY (ex. Save2)

Saves settings for future use, saves vary from 0 to 9

 

 

RecallY (ex. Recall2)

RecallY (ex. Recall2)

Pulls up saved settings for the number you selected

 

 

ClearY (ex. Clear2)

ClearY (ex. Clear2)

Erases the save for the number you selected

 

 

Mreset

Mreset

Sets matrix back to the default settings

 

 

 

 

 

 

Each command or feedback is terminated with a carriage return.

Note: If the command fails or is incorrect the feedback should be “Command FAILED”