RS232 CONTROL:
Baud Rate: | 9600 bps |
Data bits: | 8 bits |
Parity: | None |
Stop bits: | 1 bit |
Flow control: | None |
RS232 Cable Wiring:
Pin Definition
1NC
2Tx
3Rx
4NC
5GND
6NC
7NC
8NC
9NC
Controller
Pin Definition
1NC
2Rx
3Tx
4NC
5GND
6NC
7NC
8NC
9NC
Note: ‘ ’ is carriage return.
OUTPUT | COMMAND | ACTION |
| cir 00 | Output 1 select Input1 |
| cir 01 | Output 1 select Input2 |
| cir 02 | Output 1 select Input3 |
Output 1 | cir 03 | Output 1 select Input4 |
| cir 04 | Output 1 select Input5 |
| cir 05 | Output 1 select Input6 |
| cir 06 | Output 1 select Input7 |
| cir 07 | Output 1 select Input8 |
< | cir 08 | Output 1 select Input previous |
> | cir 09 | Output 1 select Input next |
| cir 10 | Output 2 select Input1 |
| cir 11 | Output 2 select Input2 |
| cir 12 | Output 2 select Input3 |
Output 2 | cir 13 | Output 2 select Input4 |
| cir 14 | Output 2 select Input5 |
| cir 15 | Output 2 select Input6 |
| cir 16 | Output 2 select Input7 |
| cir 17 | Output 2 select Input8 |
< | cir 18 | Output 2 select Input previous |
> | cir 19 | Output 2 select Input next |
www.atlona.com toll free: |
| |
9 | ||
For International: | ||
|