LOW BATTERY INDICATOR
The Low Battery Indicator is another feature that is programmed into your SMART scope. Led “B” starts to glimmer when the batteries start losing voltage and needed to be replaced.
FOCUSING
To focus the Aries 6500 you need to adjust the diopter first thing. Simply turn the diopter clock wise until it stops. Then concentrate on any object and slowly turn the diopter back counter clockwise until the grain in the image is sharp.
NOTE: The diopter should be focused during day light with the filter on. Focus the front lens so the image and the grain are both sharp. When you are in the
NOTE: The front lens should be readjusted corre spond- ingly for viewing objects at different distances.
CLEANING THE EYEPIECE
You may need to clean the eyepiece end in order to guarantee top performance. When you receive your Aries 6500 you should check for dust on the eyepiece of the unit.
On the Aries Mk 6500 simply turn the eyepiece
Once the eyepiece section has been removed from your Aries scope you may clean the dust off the glass surfaces and the phosphor screen of the light intensifier tube. When reinserting the eyepiece into the scope make sure it is seated tightly with the internal rubber bushings.
CAUTION: Use only Photographic lens cleaning tissue on these surfaces. Be careful not to scratch or smudge any of them. When using compressed air to blow the dust away make sure to avoid invert- ing the can while spraying. This may cause the frozen propellant to exit the can and cause serious
problems with the glass and phosphor screens.
5