Trouble shooting

The mapping panel is also very useful for troubleshooting. Clicking the SCAN button displays a list of the Fibre Channel port(s) and the SCSI Target devices, as well their status (online/offline).

If a target is not detected or is listed as offline in the STATUS field, check the device itself, the SCSI cabling, and the SCSI termination.

If all targets for a particular SCSI Bus are not detected or are all listed as offline in the STATUS field, chances are the SCSI Bus within the bridge itself has failed. Call the place of purchase for a repair order.

If a Fibre Port is listed as offline in the STATUS field, chances are the Fibre Port within the bridge itself has failed. Call the place of purchase for a repair order.

Mapping

Some options will be “grayed out” on the panel: they are not available because of the type of access mode or FibreBridge model or they have no effect based on other

selections. The chart below shows options available based on model and access method.