Aube Technologies TH104 Techn I Cal Speci Fi Cation S, About Temperature Con Trol, Warranty

Models: TH104

1 5
Download 5 pages 34.82 Kb
Page 4
Image 4
TECHN I CAL SPECI FI CATION S

TECHN I CAL SPECI FI CATION S

Model: TH104

Supply: 120/240 VAC, 50/60 Hz

Power consumption (off): 860 mW

Load: 14.6 A maximum (resistive only), 2 A minimum

Power: 1750 W @ 120 VCA / 3500 W @ 240 VCA

Temperature display range: 0°C to 99°C (0°F to 99°F)

Temperature setting range: 5°C to 27 °C (40°F to 80°F)

Display resolution: 1°

Storage temperature: -20°C to 50°C (-4°F to 120°F)

Accuracy: proportional: ± 0.15°C (0.27°F) from the setpoint conventional: ± 0.5°C (0.9°F) from the setpoint

Approval: CSA / UL

Dimensions: 120 x 115 x 26 mm (4.8 x 4.5 x 1 inch)

ABOUT TEMPERATURE CON TROL

The TH104 works differently than conventional electromechanical thermostats which can have a temperature differential up to 4°C and 5°C. The TH104 has a temperature differential of ± 0.15°C from the setpoint. This slight oscillation eliminates the discomfort often found with conventional electromechanic thermostats.

For each cycle, the proportional controller determines the “On” operating time required by the heating system to maintain the set- point temperature. The following table displays the percentage of the “On” operating time for the heating cycle:

 

 

 

 

1 to 25%

26 to 50%

51 to 75%

76 to 100%

 

 

 

 

If you are using the conventional control (fan-forced heater), the screen will show the FAN indicator as well as all flame icons ( ABOUT TEMPERATURE CON TROLTECHN I CAL SUPPORTWARRANTYAube Technologies Inc. ) when the system is activated. In this case, the thermostat differen- tial is ± 0.5°C from the setpoint.

NOTE: The temperature display resolution is 1°C, but the tempera- ture is internally controlled at 0.01°C.

TECHN I CAL SUPPORT

If you have any questions concerning the installation of the TH104 thermostat, contact our technical support team at:

Tel.: (450) 358-4600

1-800-831-AUBE (2823)

Fax: (450) 358-4650

Email: service@aubetech.com

Monday to Friday from 8:30 AM to 5:00 PM EST

For more information on our products, visit us at

www.aubetech.com

WARRANTY

AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY

This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held lia- ble for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address:

Aube Technologies Inc.

705 Montrichard

Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8

PROBLEM

POSSIBLE CAUSE

 

SOLUTION

 

 

 

 

 

 

No display

Circuit breaker is open

Verify voltage presence at the thermostat

 

Power failure

 

 

 

 

 

Thermostat is hot

In normal use, at full capacity (3000 W), the thermostat

This state is normal and does not affect temperature

 

housing may reach a temperature of 35°C to 40°C

control

 

 

 

 

Displayed temperature is

• A draft is near the thermostat

Eliminate the draft

wrong

• The sticker is still on the thermostat display

Remove the sticker

 

 

 

The lights are flickering

Fast current switching in the baseboards, mainly in rural

• Use conventional control mode

 

regions

 

See Options selection section

 

 

 

 

System is always on

Bad installation

Verify installation

 

 

• Reset the thermostat: press PROGRAM while

 

 

 

resetting the unit, release PROGRAM (see Options

 

 

 

selection section)

 

 

 

 

Screen shows the heating icon,

• Bad installation

Verify installation

but the system is not heating

• Power failure (LP indicator is displayed)

 

 

 

 

 

 

03/06/2004

4/4

400-104-000-A

Page 4
Image 4
Aube Technologies TH104 Techn I Cal Speci Fi Cation S, About Temperature Con Trol, Techn I Cal Support, Warranty, Problem