Troubleshooting

Problem

 

Possible Cause

 

Solution

Regulator coupling nut is not fully connected to LP cylinder

LP-Excess flow valve tripped in regulator

Vapor lock in connections

Tighten coupling nut by hand about one-half to three quar- ters additional turn. Do not use tools.

Turn Control Knobs to “Off” position and turn LP Gas Cyl- inder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at LP Gas Cylinder and grill. Disconnect the regulator from the LP Gas Cylinder. Reconnect the regulator to the LP Gas Cylinder. This will reset the excess flow valve Perform a leak test. Relight grill.

 

 

Obstructions in Burners

 

 

Wet Electrodes and Burners

 

 

Wire loose or disconnected

 

 

Wire shorting (sparking

 

 

between Igniter and Electrode)

 

 

 

IR side burner will not

 

Thermocouple is not properly

stay lit

 

attached to side burner valve.

 

 

Safety sensor is not completely

 

 

heated

 

 

 

IR side burner will not

 

IR side Burner has filled with

light using ignitor or

 

water

match

 

 

 

 

 

Burners will not light

 

Burners not assembled correctly

using a match

 

 

 

 

LP Gas Cylinder is empty

 

 

LP-Excess flow valve tripped in

 

 

regulator

Clean the Burners. See “How to Clean Burners” in Care and Maintenance.

Dry Electrode with clean cloth. Air dry or use blow dryer.

Reconnect the wire.

Replace Igniter Wire/Electrode assembly. (Call the Customer Service Department)

See Step 14C Page 13

Follow lighting proceedure but hold control knob IN for at least 10 seconds.

Blow water out of ceramic center of burner.

Close lid when not in use.

See re-assembly after cleaning in Care and Maintenance.

Take LP Gas Cylinder to licensed LP gas supplier to be refilled.

Turn Control Knobs to “Off” position and turn LP Gas Cyl- inder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at LP Gas Cylinder and grill. Disconnect the regulator from the LP Gas Cylinder. Reconnect the regulator to the LP Gas Cylinder. This will reset the excess flow valve Perform a leak test. Relight grill.

Regulator Coupling nut is not fully connected to LP Gas Cylinder

Obstructions in Burners

Low flame or low heat LP-gas in LP Gas Cylinder is low

Excess flow valve tripped in regulator

Tighten Regulator Coupling nut by hand about one-half to three quarters additional turn. Do not use tools.

See “How to Clean Burners” in Care and Maintenance.

Check LP Gas Cylinder. Refill if necessary.

Turn Control Knobs to “Off” position and turn LP Gas Cyl- inder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at LP Gas Cylinder and grill. Disconnect the regulator from the LP Gas Cylinder. Reconnect the regulator to the LP Gas Cylinder. This will reset the excess flow valve Perform a leak test. Relight grill.

Page 35
Image 35
Aussie 6804, 6805 manual See How to Clean Burners in Care and Maintenance