Operating Your Appliance

31

 

 

Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

Problem

Possible Cause

 

 

 

 

Smoke Enters Room During

Open the bypass (pg. 26).

 

 

 

 

Start-Up

Open the air control (pg. 28).

 

 

 

 

 

Cold Air Blockage - burn a piece of newspaper to

 

 

 

 

 

 

establish a draft.

 

 

 

 

 

If the flame is not getting enough air, a small crack in

 

 

 

 

 

 

the door is all that is needed.

 

 

 

 

 

 

 

 

 

 

Kindling Does Not Start - Fire

Open the bypass (pg. 26).

 

 

 

 

Smolders

Open the air control (pg. 28).

 

 

 

 

 

Not enough starter paper - use additional newspaper if

 

 

 

 

 

 

necessary.

 

 

 

 

 

If the flame is not getting enough air, a small crack in

 

 

 

 

 

 

the door is all that is needed.

 

 

 

 

 

 

 

 

 

 

Smoke Enters Room While Re-

Open the bypass (pg. 26) before opening the door.

 

 

 

 

Loading

Let the air stabilize before fully opening the door. Then

 

 

 

 

 

 

open the door approximately 1 inch. Let air go into the

 

 

 

 

 

 

firebox for a few seconds. Once the smoke appears to

 

 

 

 

 

 

be flowing up the chimney consistently, open the door.

 

 

 

 

 

Insufficient Draft - Chimney height and outside

 

 

 

 

 

 

conditions can negatively affect draft. In these cases a

 

 

 

 

 

 

small amount of smoke may enter the home. Adding

 

 

 

 

 

 

more pipe or a draft-inducing cap may help.

 

 

 

 

 

 

 

 

 

 

Stove Does Not Burn Hot Enough

Wood is Wet - see the section "Selecting Wood" on

 

 

 

 

 

 

page 30 for details on wood.

 

 

 

 

 

Make sure the air control is all the way open. Slide the

 

 

 

 

 

 

control back and forth to insure the control is not stuck.

 

 

 

 

 

Insufficient Draft - Chimney height and outside

 

 

 

 

 

 

conditions can negatively affect draft. In these cases

 

 

 

 

 

 

the fire may burn slowly. Adding more pipe or a draft-

 

 

 

 

 

 

inducing cap may help.

 

 

 

 

 

 

 

 

 

 

 

Blower Does Not Run

Stove is Not Up to Temperature - This is normal. The

 

 

 

 

 

 

blower will come on when the stove is hot - usually 15

 

 

 

 

 

 

to 30 minutes.

 

 

 

 

 

Electricity is Cut to the Blower - Check the household

 

 

 

 

 

 

breaker or fuse to make sure it is operable.

 

 

 

 

 

 

 

 

 

 

Stove Does Not Burn Long

Depending upon wood, draft, and other factors, the

 

 

 

 

Enough

 

burn time may be shorter then stated. Make sure the

 

 

 

 

 

doors are sealing and not allowing air into the firebox -

 

 

 

 

 

 

 

 

 

 

 

 

See the section "Door and Glass Inspection" on page

 

 

 

 

 

 

33 for details.

 

 

 

 

 

Check the ash bed for coals. Often, coals are still

 

 

 

 

 

 

glowing under a slight bed of flyash. By raking these

 

 

 

 

 

 

into a pile you can re-start your stove quickly.

 

 

 

 

 

 

 

 

 

© Travis Industries

93508061

4050526

Page 31
Image 31
Avalon Stoves 1190 owner manual Troubleshooting

1190 specifications

Avalon Stoves has long been recognized for its commitment to quality, efficiency, and performance in the realm of home heating. Among its stellar offerings, the Avalon Stoves 1190 stands out as a testament to modern innovation and classic design. This wood-burning stove caters to both functionality and aesthetics, making it an ideal addition to any home.

One of the main features of the Avalon 1190 is its impressive heating capacity. With the ability to produce up to 70,000 BTUs, this stove is capable of heating large spaces, making it perfect for open-concept layouts or larger living areas. The stove's firebox is designed to accommodate logs up to 18 inches, allowing for longer burn times and less frequent reloading.

In addition to its heating capabilities, the Avalon 1190 incorporates advanced technologies that enhance its efficiency. One notable feature is the clean-burn technology, which significantly reduces emissions while maximizing heat output. This technology not only promotes a healthier environment but also aligns with eco-friendly practices, creating a more sustainable heating option for homeowners.

The Avalon 1190 is also equipped with a secondary combustion system, which ensures that more of the wood’s energy is utilized during the burn process. This results in hotter fires and minimal smoke production, further contributing to its efficient performance. The stove's design also includes a built-in air wash system that helps keep the glass clean, allowing for a clear view of the mesmerizing flames.

Another characteristic that sets the Avalon 1190 apart is its aesthetic appeal. With a sleek and contemporary design, the stove is available in several finishes, including classic black, cast iron, and even a stylish porcelain enamel. This versatility ensures that it can seamlessly integrate into any home décor, from rustic to modern settings.

Moreover, the Avalon 1190 comes with a reliable warranty, underscoring the manufacturer's confidence in the product’s durability. Constructed with high-quality materials, this wood stove is built to last, providing warmth and comfort for years to come.

In conclusion, the Avalon Stoves 1190 is a perfect blend of high performance, innovative technology, and elegant design. Whether it’s for heating a cozy living room or creating an inviting ambiance, the Avalon 1190 remains a top choice for discerning homeowners seeking a dependable wood-burning solution. Its efficient heating capabilities, coupled with eco-friendly features, make it a model of contemporary living that respects both comfort and the environment.