12 Installation (for qualified installers only)

Approved Vent Configurations

Restrictor

Position

A restrictor is built

into the appliance to

control the flow rate

of exhaust gases.

This ensures proper

flames for the wide

To Access the Restrictor

Remove the nuts holding the stove top in place (see the illustration below). Lift the stove top off the stove.

 

To Adjust the Restrictor

a

b

Slide the restrictor

adjustment rod in.

Lift the cotter pin out.

NOTE:

 

 

The restrictor is

Restrictor

 

shipped in

Positions

# 1

position #1.

 

# 5

# 4

 

 

c

Replace the cotter pin

through the correct

hole on the restrictor adjustment rod.

variety of vent

configurations.

Depending upon

the vent

configuration, you

may be required to

adjust the restrictor

position. The charts

for approved vent

configurations

describe which

position the vent

restrictor must be in.

# 6

# 2

# 3

This restrictor is

in position # 6

3/8" Nutdriver

Measuring Vent Lengths

Vent Horizontal Run

(measure from the closest edge of

the starter section to the end of the

termination)

 

Vent

Vent Height is calculated

Height

 

to the top of the vent on

 

horizontal terminations

 

and to the top of the

 

termination on vertical

 

terminations.

 

Travis Industries

9 3 5 0 8 1 1 5

4 0 5 0 1 1 3

Page 12