12 Installation (for qualified installers only)
Approved Vent Configurations
Restrictor
Position
• A restrictor is built |
into the appliance to |
control the flow rate |
of exhaust gases. |
This ensures proper |
flames for the wide |
To Access the Restrictor
Remove the nuts holding the stove top in place (see the illustration below). Lift the stove top off the stove.
| To Adjust the Restrictor | |
a | b | Slide the restrictor |
adjustment rod in. |
Lift the cotter pin out.
NOTE: |
|
|
The restrictor is | Restrictor |
|
shipped in | Positions | # 1 |
position #1. | ||
| # 5 | # 4 |
|
|
c | Replace the cotter pin |
through the correct |
hole on the restrictor adjustment rod.
variety of vent |
configurations. |
Depending upon |
the vent |
configuration, you |
may be required to |
adjust the restrictor |
position. The charts |
for approved vent |
configurations |
describe which |
position the vent |
restrictor must be in. |
# 6
# 2
# 3
This restrictor is
in position # 6
3/8" Nutdriver
Measuring Vent Lengths
Vent Horizontal Run
(measure from the closest edge of
the starter section to the end of the
termination)
| Vent |
Vent Height is calculated | Height |
| |
to the top of the vent on |
|
horizontal terminations |
|
and to the top of the |
|
termination on vertical |
|
terminations. |
|
Travis Industries | 9 3 5 0 8 1 1 5 | 4 0 5 0 1 1 3 |