36 Optional Equipment (for qualified installers only)
Travis Industries 93508115 4050113
3Follow the directions below to remove the natural gas orifice. Apply thread sealant to the LP orifice ( ithas ".062" stamped on it) and tighten in place with a 1/2" open end wrench. Replace and secure themixing tube.
1/2" Wrench
Use a 1/2 open end wrench to
unscrew the burner orifice.
NOTE:
Screw the LP orifice in
so the orifice shoulder
protrudes 5/16
(indicating full insertion).
37
.062
The new LP orifice
has .062 stamped
on it.
The old NG
orifice has 37
stamped on it.
Apply thread
sealant to the
new orifice and
install.
5/16
Remove the four screws
holding the mixing tube in
place.
Remove the mixing tube
from the air shutter by
sliding it to the left.
1/4" Nutdriver
Air Shutter
a
b
Slide the air shutter to the fully
open position.
Manifold
Burner Orifice
c
de