Avanti ™
Security control panels
8 fully programmable Zones + PA and Tamper
External lighting facility to control up to 2000 watts of external security lighting
3 part set programs
Service timer (selectable)
Chime on any Zone
Entry/Exit timers programmable in one second increments
6 Communicator outputs (RS panels)
7 codes
Up to 4 remote keypads
K-600HW engineer manual
Introduction
Avanti is a flexible range of fully featured security control panels suitable for domestic and light commercial applications designed to meet the installation requirements of
Avanti is supplied with
With 8 fully programmable zones plus PA and tamper, doorbell, quick set, fire and the ability to control security lighting via a Drive Module the Avanti provides you with a
RS versions provide 6 digital ports for use with a wire on communicator.
EMC:
Emissions
Immunity
Low Voltage Directive (LVD) 73/23/EEC
1 Installation
1.1 System Design
Before commencing installation it is important to familiarise yourself with these instructions.
Care should be taken when planning the system that the control panel is sited close to a convenient mains supply and is not visible from the outside of the property.
If you are using the Avanti ES then the end station may be located in a cupboard in the hall or under the stairs. The remote keypads should be located so that the user can access them easily during entry and exit.
1.2Fixing
First disconnect the AC and internal speaker wiring, releasing the PCB from the case.
Offer the case to the wall, mark, drill and plug for three hole fixing using a suitable bit.
Where required remove trunking cut outs and drill wall for cable entry.
Screw in top fixing (No8 x 212”screw) and leave protruding 12”, mount the box utilising the keyhole, align and secure using 2 off No8 x 212” screws.
Refit the PCB and reconnect the speaker and AC wires.
1.3 Pre-installation test
Observing the correct polarity, Connect the battery to the terminals marked Batt + -
The panel will now go into alarm condition. Entering the user code (0123) will silence the system. The Tamper and Power LED’s will be lit with Day & Zone flashing. To reset the panel
Upon completion of initial test, disconnect the battery.
1.4 Wiring
Wire each of the zones in turn making sure to connect tampers in series then continue to wire PA, internal and external sounder and strobe and any additional remote keypads. Finally on RS models connect any communicating devices.
1.5RKPs
Up to 4 RKP’s may be wired in parallel with the tamper being wired in series using a single
1.6 Utility Outputs
A unique feature of the Avanti is the ability to operate security lighting. To utilise this
To install floodlights the LDM is wired into the RKP terminals and lighting is operated through Channels A & B. Depressing the A or B keys on the control panel will switch up to 1000 watts per channel (total available 2000 watts).
If you choose to install a PIR then this can be wired into any unused zone which when activated will switch the lighting on for a period of 15 seconds.
1.7Mains Connection
This equipment should be installed by a suitably qualified electrician and must be wired with cable rated at least 1 Amp, 230 volts AC. Ensure that a suitable disconnect device such as a fused spur or removable fuse is fitted to the mains supply.