7. Verification Steps
The following steps may be used to verify the configuration of PoE related parameters:
∙Verify that the PoE Operational Status in ON at the system level by entering the command show
ProCurve Switch
Status and Counters - System Power Status
Operational Status : On
Usage Threshold (%) : 80
Chassis
Total Available | Power | : | 195 | W | |
Total | used Power | : | 5 | W +/- 6W | |
Total | Remaining | Power | : | 190 | W |
∙Verify that Power Enable is Yes at the port level by entering the command show power- management brief.
ProCurve Switch 2520-24-PoE# show power-over-ethernet brief
Status | and Counters - Port | Power | Status |
|
|
|
| ||
PoE | Power | Power | Alloc | Alloc | Actual Configured | Detection | Power | ||
Port | Enable | Priority | By | Power | Power Type | Status | Class | ||
+ | |||||||||
1 | Yes | low | usage | 17 | W | 0.0 | W | Delivering | 0 |
2 | Yes | low | usage | 17 | W | 0.0 | W | Searching | 0 |
3 | Yes | low | usage | 17 | W | 0.0 | W | Searching | 0 |
4 | Yes | low | usage | 17 | W | 0.0 | W | Searching | 0 |
5 | Yes | low | usage | 17 | W | 0.0 | W | Searching | 0 |
6 | Yes | low | usage | 17 | W | 0.0 | W | Searching | 0 |
7 | Yes | low | usage | 17 | W | 0.0 | W | Searching | 0 |
8 | Yes | low | usage | 17 | W | 0.0 | W | Searching | 0 |
9 | Yes | low | usage | 17 | W | 0.0 | W | Searching | 0 |
10 | Yes | low | usage | 17 | W | 0.0 | W | Searching | 0 |
11 | Yes | low | usage | 17 | W | 0.0 | W | Searching | 0 |
12 | Yes | low | usage | 17 | W | 0.0 | W | Searching | 0 |
TMA; Reviewed: | Solution & Interoperability Test Lab Application Notes | 7 of 10 |
SPOC 11/16/2009 | ©2009 Avaya Inc. All Rights Reserved. |