Sharp KC-840E Plasmacluster ON/OFF Button, Water Supply Indicator Light, LIGHTS CONTROL Button

Models: KC-850E KC-860E KC-840E

1 108
Download 108 pages 23.32 Kb
Page 12
Image 12
Press the Fan Speed Button to set the desired sensor sensitivity.
With the unit OFF, press the Fan Speed Button for 3 seconds.
The Fan Speed Indicator Lights will display the currently set sensor sensitivity level. The factory setting is Standard, indicated by the MED light.

OPERATION

Plasmacluster ON/OFF Button

Press the Plasmacluster ON/OFF Button to turn Plasmaclus- ter Ion Mode ON and OFF.

When Plasmacluster is ON, both the Indicator Light and Plasmacluster Indicator Light turn on.

LIGHTS CONTROL Button

Use when the light on the front panel is too bright.

Refer to the diagram on the right to select the desired brightness on the front panel.

 

 

 

 

 

 

 

The lights on the front panel are brighter..

 

 

The lights on the front panel are darker..

 

 

The lights on the front monitor turn off.

 

 

 

 

 

CAUTION The lights on the front monitor are always brighter when starting.

WATER SUPPLY INDICATOR LIGHT

When the Water Tank is empty, the Water Supply Indicator Light will fl ash to indicate that the Water Tank should be refi lled. Please note the light will not flash even when the Water Tank is empty during the Clean Air Mode and the Clean ION SHOWER Mode.

Sound indicator setting for water supply.

Flashing

In addition to the Indicator Light, the unit can be set to signal with an audible beep when the Water Tank is empty. With the unit OFF, press the Lights Control button for 3 seconds to turn the audible signal ON.

Cancellation

To cancel the audible signal, with the unit OFF, press the Lights

Control button again more than 3 seconds.

ADJUSTMENT OF SENSOR DETECTION SENSITIVITY

Set to “low” if the DUST MONITOR and ODOUR MONITOR is constantly red to reduce sensitivity, and set to “high’ if the DUST MONITOR and ODOUR MONITOR is constantly green to increase sensitivity.

1

2Refer to the diagram on the right to select the desired sensor sen- sitivity level.

3 Press the Power OFF Button.

Note that if the Power OFF Button is not pushed within 8 seconds of adjusting sensor sensitivity, the setting will be saved automati- cally. The sensor sensitivity setting will be saved even if the unit is unplugged.

Fan Speed

Sensor

Indicator

Detection

Light

sensitivity

 

High

 

Standard

 

Low

E-0

Page 12
Image 12
Sharp KC-840E Plasmacluster ON/OFF Button, Water Supply Indicator Light, LIGHTS CONTROL Button, Operation, Cancellation