Sharp KC-850E, KC-840E, KC-860E operation manual Specifications, E-18, Standby Power

Models: KC-850E KC-860E KC-840E

1 108
Download 108 pages 23.32 Kb
Page 20
Image 20

E-18

Model

 

 

KC-860E

 

 

KC-850E

 

 

KC-840E

 

Power supply

 

 

 

 

220 ~ 240 V  50/60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Speed Adjustment

MAX

MED

LOW

MAX

MED

LOW

MAX

MED

LOW

 

Fan Speed (m3/hour)

396

240

84

306

168

60

210

132

48

CLEAN AIR

 

 

 

 

 

 

 

 

 

 

Rated Power (W)

56

19

5.5 (4.9)

41

11.6

3.8 (3.3)

26

9.5

3.7 (3.4)

 

 

 

 

 

 

 

 

 

 

 

 

Noise Level (dBA)

51

39

17

47

35

15

45

34

15

 

 

 

 

 

 

 

 

 

 

 

 

Fan Speed (m3/hour)

396

240

120

288

168

84

186

132

54

CLEAN AIR

Rated Power (W)

56

21

8.8 (8.2)

40

13.5

6.8 (6.3)

21

11.5

6.1 (5.8)

& HUMIDIFY

 

 

 

 

 

 

 

 

 

 

Noise Level (dBA)

50

39

25

47

35

22

42

34

20

 

 

 

 

 

 

 

 

 

 

 

 

Humidification (mL/hour)*2

730

500

300

600

400

230

450

330

170

 

 

 

 

 

 

 

 

 

 

 

Recommended

Room Size (m2)*1

 

~48

 

 

~38

 

 

~26

 

Water Tank Capacity (L)

 

4.3

 

 

4.0

 

 

3.0

 

 

 

 

 

 

 

 

Sensors

 

 

Dust/odour/Temperature & Humidity

 

Dust/Temperature & Humidity

 

 

 

 

 

 

 

 

 

Filter type

Dust collection

 

 

 

HEPA with Microbial control *3

 

 

 

 

 

 

 

 

 

 

 

 

 

Deodorization

 

 

 

Washable Deodorizing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cord Lenght (m)

 

 

 

 

2.0

 

 

 

 

 

 

 

 

Dimensions (mm)

398 (W) × 288 (D) × 627 (H)

378 (W) × 265 (D) × 586 (H)

360 (W) × 233 (D) × 550 (H)

 

 

 

 

 

 

 

 

 

 

 

Weight (kg)

 

 

11.0

 

 

9.0

 

 

8.0

 

 

 

 

 

 

 

 

 

 

 

 

*1 • The Recommended Room Size is appropriate for operating the unit of maximum fan speed.

• The Recommended Room Size area indicates the space where a certain amount of dust particles can be removed in 30 minutes.

*2 • Humidification Amount changes in accordance with indoor and outdoor temperature and humidity. Humidification Amount increases as temperatures rise or humidity decreases.

Humidification Amount decreases as temperatures decrease or humidity rises. • Measurement Condition: 20 ºC, 30 % humidity (JEM1426)

*3 • The class of the HEPA filter by EN1822 is H10.

Standby Power

In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product consumes about 0.7 W of standby power.

For energy conservation, unplug the power cord when the unit is not in use.