For example, follow the steps above to change ports
Figure 7 shows all three ports are configured to use the Guaranteed profile. Note the power limit is set to 15.4 watts for ports 1 and 2, and 7 watts for port 3, since both the 4620 and 4612 IP telephones are class 3 devices and the 4602SW IP phone is a class 1 device.
Table 2 shows the required power allocations defined by IEEE 802.3af-2003, based on the class.
Class | Usage | Power |
|
| (Watts) |
0 | Default | 15.4 |
1 | optional | 4 |
2 | optional | 7 |
3 | optional | 15.4 |
Table 2: IEEE 802.3af-2003 Power Classes
Figure 7: Port Inline Power Profile Configuration