IMPORTANT SAFETY WARNINGS

FOR INSTALLATION

When this product is located in a separate building from the telephone communications system, a line current protector MUST be installed at the entry/exit points of ALL buildings through which the line passes.

Only one protector is needed at each installation point.

For 2-wire installations, the following is recommended:

Lucent Technologies 4-type protectors

ITW LINX LP-type protectors.

Lucent Technologies 3BIC (carbon block) or Lucent 3BEW (gas tube) protectors are also acceptable in a 2-wire installation.

INSTALLATION WARNING

(for the CALLMASTER VI)

MODULAR WALL JACK WIRING

Pin

Pair

Name

Description

4

1

BL-W

2-Wire (Tip)

5

1

W-BL

2-Wire (Ring)

FAILURE TO FOLLOW THESE INSTRUCTIONS CAN CAUSE DAMAGE TO THE TERMINAL OR CAUSE THE ASSOCIATED DEFINITY® ECS CIRCUIT PACK TO REMOVE POWER TO THE TERMINAL. IN EITHER CASE, THE TERMINAL WILL NOT FUNCTION CORRECTLY.

For 2-wire operation, if you need to plug the voice terminal into a 4-pin or 6-pin wall jack, instead of a standard 8-pin modular jack, see the Modular Wall Jack Wiring table to ensure that the wires from the 4-pin or 6-pin wall jack are connected to the correct pins on the terminal LINE jack.

Two-wire installations must have only PBX connections on pair 1.

This information applies to the CALLMASTER® VI.

Page 6