E. Junction Box Installation
If the box is being wired from the INSIDE of the appli- ance:
•Remove the screw attaching the junction box/receptacle to the outer shell, rotate the junction box inward to dis- engage it from the outer shell (see Figure 12.3).
•Pull the electrical wires from outside the appliance through the opening into the valve compartment and secure wires with a Romex connector. See Figure 12.3.
•Make all necessary wire connections to the junction box/receptacle and reattach the junction box/receptacle to the outer shell.
F. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.4):
•The power supply for the appliance must be brought into a switch box.
•The power can then be supplied from the switch box to the appliance using a minimum of
•At the switch box connect the black (hot) wire and red (switch leg) wire to the wall switch as shown.
•At the appliance connect the black (hot), white (neutral) and green (ground) wires to the junction box as shown.
•Add a 1/4 in. insulated female connector to the red (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown.
| Romex | |
| Connector | |
| 14/2WG | |
| Cover Plate | |
| outside firebox | |
WHT |
| |
BLK |
| |
WHT |
| |
BLK | Copper | |
| ||
GRN wire | ground attached | |
to GRN screw with | ||
inside box | ||
| GRN wire | |
NOTICE: DO NOT wire | ||
110 VAC to wall switch. | ||
Figure 12.3 Junction Box Detail |
|
Minimum |
| Switch |
|
| |
with Ground |
|
|
| Red |
|
| Black | Black |
| White | White |
Junction Box | Green | Green |
Red Black White Green |
| Power |
| Switch Box | |
| Supply | |
|
| |
|
| Wires |
| Knockout |
|
Red |
|
|
Figure 12.4 Junction Box Wired to Wall Switch or BC10 |