Rear Vent - Vertical Termination - (continued) Two Elbows

Note: Use DVP Series components only.

H1+ H2 Maximum

V1 Minimum

1/2 ft.

152 mm

Back to Back Elbows

2-1/2 ft.

762 mm

1 ft.

305 mm

4-1/2 ft.

1.4 m

2 ft.

610 mm

6-1/2 ft.

2.0 m

3 ft.

914 mm

 

H Maximum = 6-1/2 ft. (2 m)

 

V1 + H1 + H2 Maximum = 40 ft. (12.2 m)

V1

 

 

 

INSTALLED

HORIZONTALLY H1

H2

Figure 7.16

Three Elbows

Note: Use DVP Series components only.

Figure 7.17

V2

H2

H1 Maximum

V1 Minimum

 

H2

H1 + H2

Maximum

1-1/2 ft.

457 mm

Back to Back

1 ft.

 

305 mm

2-1/2 ft.

 

762 mm

Elbows

 

 

 

 

 

 

 

 

 

 

3-1/2 ft.

1.1 m

1 ft.

305 mm

3 ft.

 

914 mm

6-1/2 ft.

 

2.0 m

 

 

 

 

 

 

 

 

 

 

5-1/2 ft.

1.2 m

2 ft.

610 mm

5 ft.

 

1.5 m

10-1/2 ft.

 

3.2 m

7-1/2 ft.

2.3 m

3 ft.

914 mm

7 ft.

 

2.1 m

14-1/2ft.

 

4.4 m

H1 Maximum = 7-1/2 ft. (2.3 m)

V1 + V2 + H1 + H2 Maximum = 40 ft. (12.2 m)

V1

H1

34