F. Vent Diagrams

Top Vent - Horizontal Termination Venting

One Elbow

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 5.3).

WARNING

Fire Risk.

• When using SLP-HRC-SS and SLP-HRC-ZC-

SStermination caps on top vented fireplaces, a one foot minimum vertical vent section is

required before installing first elbow.

When using DVP-TB1 termination cap on top vented fireplaces, a three foot minimum vertical vent section is required before installing first elbow.

Figure 7.4

V Minimum

H1 Maximum

SL-750TRSFHHIPI

 

 

 

90º Elbow

1 ft.

305 mm

1/2 ft.

 

152 mm

2 ft.

610 mm

1-1/2 ft.

 

457 mm

3 ft.

914 mm

2-1/2 ft.

 

762 mm

5 ft.

1-1/2 m

3-1/2 ft.

 

1.1 m

7 ft.

2.1 m

4-1/2 ft.

 

1.4 m

15 ft.

4.6 m

 

H1 Maximum= 15 ft. (4.6 m)

V1 + H1 Maximum= 40 ft. (12.2 m)

V1

H1

Heat & Glo • SL-750TRSFHHIPI2156-900 Rev. F • 11/08

25

Page 25
Image 25
Hearth and Home Technologies SL-750TRSFHHIPI owner manual Minimum Maximum