Hearth and Home Technologies SL-750TRSFHHIPI Electrical Service and Repair, With battery back-up

Models: SL-750TRSFHHIPI

1 77
Download 77 pages 7.44 Kb
Page 51
Image 51

TRANSFORMER

3 VAC

IGNITION MODULE 3 VAC

INTERMITTENT PILOT IGNITOR

I

NOTE: 1. Ignition module, valve, pilot, and

 

wall switch operate on 3 volts. 120 VAC is

S

required at junction box unless equipped

 

with battery back-up.

WHITE

HOT

NEUTRAL

BATTERY PACK

PLUG IN

BLACK

 

 

RED

ORANGE

GROUND TO

FIREPLACE

CHASSIS

WIRES

(TO BROWN)

ORANGE

GREEN

THERMOSTAT

WIRE ASSEMBLY

VALVE

Figure 12.1 Intellifire Ignition Wiring Diagram with Wall Switch or Thermostat

NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery back-up.

HOT

NEUTRAL

TRANSFORMER

3 VAC

PLUG IN

BLACK

 

IGNITION

INTERMITTENT

MODULE 3 VAC

PILOT IGNITOR

I

 

S

 

ORANGE

WHITE

GROUND TO

FIREPLACE

CHASSIS

BATTERY PACK

PLUG IN

RED

WIRES

(TO BROWN)

ORANGE

GREEN

REMOTE

VALVE

Figure 12.2 Intellifire Ignition Wiring Diagram with Remote Receiver

D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation.

Heat & Glo • SL-750TRSFHHIPI2156-900 Rev. F • 11/08

51

Page 51
Image 51
Hearth and Home Technologies SL-750TRSFHHIPI owner manual Electrical Service and Repair, With battery back-up