Top Vent - Horizontal Termination

- (continued)

 

 

Three Elbows

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V1 Minimum

H1 Maximum

 

H1 + H2 Maximum

V2

V1 + V2 Minimum

 

 

 

 

 

 

 

 

 

Elbow only

1 ft.

305 mm

 

2 ft.

610 mm

*

*

 

 

 

 

 

 

 

 

 

1/2 ft.**

152 mm

2 ft.

610 mm

 

4 ft.

1.2 m

*

*

1-1/2 ft.**

457 mm

3 ft.

914 mm

 

6 ft.

1.8 m

*

*

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 5.3).

H2

V2

H1V1

WARNING **

Fire Risk.

When using SLP-HRC-SS and SLP-HRC-ZC- SS termination caps on top vented fireplaces,

a one foot minimum vertical vent section is required before installing first elbow.

When using DVP-TB1 termination cap on top vented fireplaces, a three foot minimum vertical vent section is required before installing first elbow.

Figure 7.6

Heat & Glo • SL-750TRSFHHIPI2156-900 Rev. F • 11/08