Top Vent - Vertical Termination

No Elbow

Note: Use SLP Series components only.

Note: If installing a vertical vent/termination off the top of the appliance, the optional vertical termination baffle may be needed.

V1 = 60 ft. Max. (18.3 m)

V1

Figure 7.7

Exhaust restrictors are recommended for these verti- cally terminated products which have excessive draft. Exhaust restrictors will compensate for high draft, and restore visual flame height. If the vent configuration has a total vertical of 15-60 feet, an exhaust restrictor may be needed. The exhaust restrictor can be located in the appliance manual bag.

Exhaust restrictor Instructions

1.Install the exhaust restrictor over the center of the ex- haust outlet in the firebox (see Figure 7.8).

2.Center the exhaust restrictor in the open end of the exhaust outlet and secure through the slots on the ex- haust restrictor with the 2-1/4 in. self tapping screws provided in the appliance manual bag.

INNER HEAT SHIELD

To access the exhaust openings, remove the inner heat shield. To remove inner heat shield, remove the two screws.

Top Vent Application

Exhaust restrictor

Rear Vent Application

Exhaust restrictor

Note: Be sure to re- install the inner heat shield after exhaust restrictor installation.

Figure 7.8

28

Heat & Glo • SL-750TRSFHHIPI2156-900 Rev. F • 11/08