5 Framing and Clearances

A. Selecting Appliance Location

When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1).

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.

A

L

F

A

C

K

J

J

M

N

D

C

B

I

G

E

F

A

G

Models

A

B

C

D

E

F

G

H

I

J

K

L

M

N

Min.

Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in.

45-1/2

42

64-3/8

See Section

1

1/2

45-1/2

64-3/8

16-1/4

48-1/2

68-3/4

16-5/8

7-1/2

9

SL-750TRSFHHIPI

 

 

 

 

D for Alcove

 

 

 

 

 

 

 

 

 

 

mm

1155

1067

1635

25

13

1155

1635

413

1232

1737

422

191

229

 

Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5.1 Appliance Locations