Top Vent - Horizontal Termination - (continued)

Two Elbows

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 5.3).

V Minimum

 

 

H Maximum

 

 

 

 

 

 

SL-750TRSFHHIPI

 

 

 

 

90º Elbow

 

 

NOT ALLOWED

1/2 ft.*

 

152 mm

1 ft.

 

305 mm

1-1/2 ft.*

 

457 mm

2 ft.

 

610 mm

2-1/2 ft.*

 

762 mm

4 ft.

 

1.2 m

3-1/2 ft.

 

1.1 m

6 ft

 

1.8 m

4-1/2 ft.

 

1.4 m

14 ft.

 

4.3 m

H1 + H2 Maximum= 14 ft. (4.3 m)

V1 + H1 + H2 Maximum= 40 ft. (12.2 m)

* See warning below

WARNING *

Fire Risk.

• When using SLP-HRC-SS and SLP-HRC-ZC-

SStermination caps on top vented fireplaces, a one foot minimum vertical vent section is

required before installing first elbow.

When using DVP-TB1 termination cap on top vented fireplaces, a three foot minimum vertical vent section is required before installing first elbow.

H2

V1

H1

 

INSTALLED

HORIZONTALLY

Figure 7.5

26

Heat & Glo • SL-750TRSFHHIPI2156-900 Rev. F • 11/08

Page 26