Avaya ALGO-3226-CM manual Configure Station, Call Routing to Algo 3226 Trunk Port FXO Doorphone

Models: ALGO-3226-CM

1 8
Download 8 pages 22.56 Kb
Page 5
Image 5
5.2. Configure Station

5.2. Configure Station

Use the add station command to add a station for the door attendant that will be called when the call button on the 3226 Doorphone is pressed. The following is a basic H.323 station that was used for this purpose. Other types of stations, like SIP, may also be used.

add station 77301

 

Page

1 of 5

 

 

STATION

 

 

Extension:

77301

Lock Messages?

n

BCC: 0

Type:

9620

Security Code: ****

TN: 1

Port: IP

Coverage Path 1:

 

COR: 1

Name: Door Attendant

Coverage Path 2:

 

COS: 1

 

 

Hunt-to Station:

 

 

 

 

 

 

 

STATION OPTIONS

 

 

 

 

 

Time of Day Lock Table:

 

Loss Group:

19

Personalized Ringing Pattern:

1

 

 

Message Lamp Ext:

77301

Speakerphone:

2-way

Mute Button Enabled? y

Display Language: english

 

 

Survivable GK Node Name:

 

 

 

Survivable COR: internal

Media Complex Ext:

 

Survivable Trunk Dest? y

IP SoftPhone? n

 

 

 

 

IP Video? n

Short/Prefixed Registration Allowed: default

Customizable Labels? y

5.3. Call Routing to Algo 3226 Trunk Port FXO Doorphone

To route calls to the doorphone, a uniform dialplan and AAR routing was used. In the Uniform- Dialplan form add an entry for extension 77777. When this extension is dialed, the call will be routed using AAR to the doorphone.

change uniform-dialplan 7

 

Page

1 of

2

 

UNIFORM DIAL PLAN TABLE

 

 

 

 

 

Percent Full: 0

 

 

 

 

 

 

 

Matching

 

Insert

Node

 

 

Pattern

Len Del

Digits

Net Conv Num

 

 

77777

5 0

 

aar n

 

 

 

 

 

 

 

 

In the AAR Analysis form, add entry for 77777 to route calls to the Route Pattern 100, which specifies the loop start trunk connected to the doorphone.

change aar analysis 7

 

 

 

 

 

Page

1 of

2

 

 

AAR DIGIT ANALYSIS TABLE

 

 

 

 

 

 

 

Location: all

 

Percent Full: 1

 

Dialed

Total

Route

Call

Node

ANI

 

 

String

Min

Max

Pattern

Type

Num

Reqd

 

 

77777

5

5

100

aar

 

n

 

 

JAO; Reviewed:

Solution & Interoperability Test Lab Application Notes

 

5 of 8

SPOC 11/3/2011

©2011 Avaya Inc. All Rights Reserved.

 

Algo-3226-CM

Page 5
Image 5
Avaya ALGO-3226-CM manual Configure Station, Call Routing to Algo 3226 Trunk Port FXO Doorphone