| | | | Chapter 3 Avaya M770 Hub Components |
| M-SPV/M-SPX Front Panel | | | |
| | | | Figure 3.3M-SPX Front Panel |
| Table 3.4 M-SPV/M-SPX Front Panel LEDs |
| LED Name | Represents | State | Function |
| | | On | Module is |
| | Module | | functioning |
| | | normally |
| OPR | Operationa | |
| | |
| | l Status | Blinkin | Module is |
| | |
| | | g | faulty |
| | | On | Main/active |
| | Main/ | | M-SPV/M-SPX |
| MAIN | Off | Backup/ |
| Backup |
| |
| | | | dormant |
| | | | M-SPV/M-SPX |
New M-SPX Functionality
IDS Switch (M-SPX only)
The M-SPX front-panel Inter-Domain Switch (IDS) enables you to combine the two Avaya M770 X-Domains, effectively doubling the available port count. Set the switch ON or OFF as required.
Caution: When installing two M-SPX modules, the IDS switch must be set to the same position on both modules.
Sideband Port SB2-ETH
Two RJ-45 Sideband ports, SB1-ETH and SB2-ETH, on the Avaya M770 hub front panel are supported by the M-SPX (see Figure 3.1). The M-SPV supports only the SB1-ETH port.
Resetting the M-SPV/M-SPX
Each M-SPV/M-SPX can be reset individually via a reset button on the Control Panel (see page 10) or using the reset button on the M-SPV/M-SPX module itself. Resetting the M-SPV/M-SPX does not reset the entire hub (for details on resetting the hub, see page 10).
Avaya M770 User’s Guide | 13 |