Trouble Shooting
Symptoms | Probable Cause | Corrective Action |
|
|
|
Timer does not move but | Hold Switch turned on. | Hold Switch should be turned off. |
press operates |
|
|
|
|
|
| Defective timer. | Replace timer. |
|
|
|
No heat / no movements | Bad fuse. | Check and / or replace fuse. |
|
|
|
| No power. | Check power to its source. |
Timer moves / heat works | Lack of air pressure |
No movement | Binding cylinder |
| Bad |
Check main airline.
Disconnect main air line, attempt to move cylinder by hand, loosen air line from
No heat / no indicator light, | No power | Check wiring | |
no meter indicator |
|
| |
|
|
| |
No heat / no indicator light. | Bad probe | Replace probe. | |
Meter reads +50 |
|
| |
|
|
| |
Heat out of control | Unit malfunctions. | Replace Unit | |
|
|
| |
| Probe shorted. | Replace probe. | |
|
|
| |
Heat working, meter not in | Error in manual reset control | Reset according to Athens Booklet. | |
the green band |
|
| |
|
|
| |
Air leak at | Internal leak in cylinder | Replace or rebuild cylinder | |
exhaust |
|
| |
|
|
| |
| Jammed | Replace | |
|
|
| |
Timer will not reset | Reset switch not functioning | Adjust or replace | |
|
|
| |
Vacuum arm stays in the | a) Foot pedal not held down until | 1) Hold down until timer hits zero | |
down position | |||
timer hits zero |
| ||
|
| ||
| b) Hold Switch turned on | 2) Hold Switch must be off during normal | |
|
| operation. | |
| c) Timer malfunction | 3) Replace timer | |
| d) | 4) Replace | |
Vacuum arm stays in up | Reset Switch not functioning | Replace or adjust | |
position after cycle | |||
|
| ||
|
|
| |
Vacuum arm has no | Broken tension spring | Replace | |
tension | |||
|
| ||
| Broken gear teeth |
|
14 • Regular Maintenance | Users Manual |