Manual Mode Configuration Button

In Manual Mode, the MH10/MH10f can be set to merge and distribute A-Net data from different combinations of ports, making signal routing easy. The functionality of the ports is determined by the setting of the Manual Mode Configuration.

One configuration is always selected (its LED is lit), even if the network is operating in Auto Mode.

One Manual Mode Configuration LED is always lit.

Press the Manual Mode Configuration button to cycle through the three options (A, B, or C). The LED next to the selected configuration will be lit regardless of the current network mode that is being used. When Manual Mode is selected at the Control Master, the selected Manual Mode Configuration is automatically applied. The corresponding LED on the front panel of the MH10/MH10f will also light when Manual Mode is active.

When multiple MH10/MH10f Merger Hubs are used in a network, note that each can be configured as needed, making complex Manual Mode networks easy to set up.

Rear Panel Features

17

Page 25
Image 25
Aviom MH10f, MH10m manual Manual Mode Configuration Button