A-Net Receive

 

 

A-Net Transmit

(Ports 1-10)

Merger

Distributor

(Ports 1-10)

1

1

 

 

2

 

 

2

3

 

 

3

4

 

 

4

5

 

 

5

6

 

 

6

7

 

 

7

8

 

 

8

9

 

 

9

10

 

 

10

Manual Mode Configuration C

Note:  When using Configuration C in Manual Mode, be sure that both MH10/MH10f Merger Hubs are set to Configuration C to avoid creating a data loop.

Configuration C Example

This example shows a stage-to-FOH application with a monitor console,

a64-channel recording split, and a broadcast feed from the front-of- house mix outputs. Two MH10 Merger Hubs are shown; MH10f hubs can be substituted.

Inputs on the stage (mic, line-level, or digital) are connected to ports 1-8 of the MH10/MH10f on stage. Port 8 on this MH10/MH10f is connected to output modules that feed the monitor console and recording devices. (Optionally, another MH10 or MH10f could be connected to port 8 to create a parallel rather than serial digital split.)

Digital audio from the stage inputs is merged and then transmitted via port 10 to the second MH10/MH10f at the front-of-house mixing position. (Port 9 is the redundant Cat-5e or fiber backup cable, shown with a dotted line in the diagram that follows.)

At FOH, port 10 is connected to four output modules which feed the front-of-house mixing console. The engineer creates mix content and sends it into an input module (marked as “Returns 1-16”) at port 5 in the diagram. Port 8 on the front-of-house MH10/MH10f is also connected to an output module located in the broadcast area. This module outputs the same FOH mix content.

24MH10 Configurations

Page 32
Image 32