AXIS M1143–L

Technical Specifications

Digital Input

3

Connect to GND to activate, or leave floating (unconnected)

0 to +40 V DC

 

 

to deactivate.

 

 

 

 

 

Digital Output

4

Internal connection to ground when activated, floating

Max load =100 mA

 

 

(unconnected) when deactivated. If used with an inductive

Max voltage = +40 V DC

 

 

load, e.g. a relay, a diode must be connected in parallel with

 

 

 

the load, for protection against voltage transients.

 

 

 

 

 

 

1

3.3 V max 50 mA

2

 

3

 

4

Performance Considerations

When settings up your system, it is important to consider how various settings and situations will affect performance. Some factors affect the amount of bandwidth (the bit rate) required, others can affect the frame rate, and some affect both. If the load on the CPU reaches its maximum, this will also affect the frame rate.

The following factors are among the most important to consider:

High image resolution and/or lower compression levels result in images containing more data. Bandwidth affected.

Access by large numbers of Motion JPEG and/or unicast H.264 clients. Bandwidth affected.

Simultaneous viewing of different streams (resolution, compression) by different clients. Effect on frame rate and bandwidth.

Accessing Motion JPEG and H.264 video streams simultaneously. Frame rate and bandwidth affected.

Heavy usage of event settings affect the product’s CPU load. Frame rate affected.

Heavy network utilization due to poor infrastructure. Bandwidth affected.

Viewing on poorly performing client computers lowers perceived performance. Frame rate affected.