AXIS 207/207W/207MW Installation Guide

Page 5

Unit connectors

Network connector - RJ-45 Ethernet connector. Supports Auto-MDIX (AXIS 207W/MW only) for automatic detection of straight or crossover cable. Using shielded cables is recommended.

Power connector - Mini DC connector. 4.9-5.1V DC, max 4.0W. See product label for ± connection.

I/O terminal connector - Used in applications for e.g. motion detection, event triggering, time lapse recording, alarm notifications, etc. It provides the interface to:

1 transistor output - For connecting external devices such as relays and LED:s. Connected devices can be activated by Output buttons on the Live View page or by an Event Type. The output will show as active (in Event Configuration > Port Status) if the alarm device is activated.

1 digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under Event Configuration > Port Status).

Auxiliary power and GND

Function

 

Pin number

Notes

Specifications

 

 

 

 

 

 

Transistor

 

Pin 4

 

Uses an open-collector NPN

Max load = 100mA

Output

 

 

 

transistor with the emitter con-

Max voltage = 24V DC

 

 

 

 

nected to the GND pin. If used

(to the transistor)

 

 

 

 

with an external relay, a diode

 

 

 

 

 

must be connected in parallel

 

 

 

 

 

with the load, for protection

 

 

 

 

 

against voltage transients.

 

 

 

 

 

 

 

Digital Input

 

Pin 3

 

Connect to GND to activate, or

Must not be exposed to

 

 

 

 

leave floating (or unconnected)

voltages greater than

 

 

 

 

to deactivate.

10V DC

 

 

 

 

 

GND

 

AXIS 207 = Pin 2

Ground

 

 

 

AXIS 207W/MW = Pin 1

 

 

 

 

 

 

 

Auxiliary DC

 

AXIS 207 = Pin 1

Electrically connected in parallel

Voltage = 4.9-5.1V DC

Power Input

 

AXIS 207W/MW = Pin 2

with the connector for the power

(all models)

 

 

 

 

supply, this pin provides an

 

 

 

 

 

auxiliary connector for mains

Min power:

Pin layouts

 

 

 

 

 

 

power to the unit.

AXIS 207: 2.5W

AXIS 207

 

 

 

4

 

 

AXIS 207W: 3.5W

 

 

 

 

This pin can also be used to

AXIS 207MW: 4.0W

 

1

 

power auxiliary equipment, with

 

 

 

 

 

a maximum current of 50mA.

 

AXIS 207MW

 

 

 

 

 

AXIS 207W

1

4

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

Page 5
Image 5