AXIS 207/207W/207MW Installation Guide | Page 5 |
Unit connectors
Network connector -
Power connector - Mini DC connector.
I/O terminal connector - Used in applications for e.g. motion detection, event triggering, time lapse recording, alarm notifications, etc. It provides the interface to:
•1 transistor output - For connecting external devices such as relays and LED:s. Connected devices can be activated by Output buttons on the Live View page or by an Event Type. The output will show as active (in Event Configuration > Port Status) if the alarm device is activated.
•1 digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under Event Configuration > Port Status).
•Auxiliary power and GND
Function |
| Pin number | Notes | Specifications | |
|
|
|
|
|
|
Transistor |
| Pin 4 |
| Uses an | Max load = 100mA |
Output |
|
|
| transistor with the emitter con- | Max voltage = 24V DC |
|
|
|
| nected to the GND pin. If used | (to the transistor) |
|
|
|
| with an external relay, a diode |
|
|
|
|
| must be connected in parallel |
|
|
|
|
| with the load, for protection |
|
|
|
|
| against voltage transients. |
|
|
|
|
|
|
|
Digital Input |
| Pin 3 |
| Connect to GND to activate, or | Must not be exposed to |
|
|
|
| leave floating (or unconnected) | voltages greater than |
|
|
|
| to deactivate. | 10V DC |
|
|
|
|
| |
GND |
| AXIS 207 = Pin 2 | Ground |
| |
|
| AXIS 207W/MW = Pin 1 |
|
| |
|
|
|
|
| |
Auxiliary DC |
| AXIS 207 = Pin 1 | Electrically connected in parallel | Voltage = | |
Power Input |
| AXIS 207W/MW = Pin 2 | with the connector for the power | (all models) | |
|
|
|
| supply, this pin provides an |
|
|
|
|
| auxiliary connector for mains | Min power: |
Pin layouts |
|
|
| ||
|
|
| power to the unit. | AXIS 207: 2.5W | |
AXIS 207 |
|
|
| ||
4 |
|
| AXIS 207W: 3.5W | ||
|
|
|
| This pin can also be used to | AXIS 207MW: 4.0W |
| 1 |
| power auxiliary equipment, with |
| |
|
|
|
| a maximum current of 50mA. |
|
AXIS 207MW |
|
|
|
|
|
AXIS 207W | 1 | 4 |
|
| |
|
|
| |||
|
|
|
|
|
|
ENGLISH