AXIS 225FD - Troubleshooting 53

Emergency Recovery Procedure

If power to the AXIS 225FD is lost during the upgrade, the process will fail and the unit will become unresponsive. A flashing red Status LED indicates a failed upgrade. To recover the unit, follow the steps below. The serial number is found on the label attached to the bottom of the camera.

1.UNIX/Linux - From the command line, type the following: arp -s <IP address of AXIS 225FD> <Serial number> temp ping -s 408 <IP address of camera>

Windows - From a command/DOS prompt, type the following: arp -s <IP address of AXIS 225FD> <Serial number>

ping -l 408 -t <IP address of camera>

2.If the unit does not reply within a few seconds, restart it and wait for a reply. Press CTRL+C to stop Ping.

3.Open a browser and type in the camera’s IP address. In the page that appears, use the Browse button to select the upgrade file to use, e.g. axis225fd.bin. Then click the Load button to restart the upgrade process.

4.After the upgrade has completed (1-10 minutes), the unit will automatically restart and show a steady green on the Power and Status LEDs and flashing green or amber on the Network LED.

5.Reinstall the AXIS 225FD.

If the emergency recovery procedure does not get the camera up and running again, please contact Axis support at www.axis.com/techsup/

Axis Support

If you contact Axis support, please help us to help you solve your problems, by providing the server report, the log file and a brief description of the problem.

Server Report - go to Setup > System Options > Support Overview. The server report contains important information about the server and its software, as well as a list of the current parameters.

The Log file is available from Setup > System Options > Logs & Reports. The Log file records events in the unit since the last system restart and can be a useful diagnostic tool when troubleshooting.

Symptoms, Possible Causes and Remedial Actions

Hardware problems

Cannot close dome casing

Problems setting the IP address

Check that the safety cord is not twisted or in the way of the camera optics.

When using ARP/Ping

Try the installation again. The IP address must be set within two minutes after running the ARP command. Ensure the Ping length is set to 408.