AXIS M3027–PVE Fixed Dome Network Camera

Hardware Overview

NOTICE

The product shall be connected using a shielded network cable (STP). All cables connecting the product to the network shall be intended for their specific use. Make sure that the network devices are installed in accordance with the manufacturer’s instructions. For information about regulatory requirements, see Electromagnetic Compatibility (EMC) on page 2 .

I/O Connector

Use with external devices in combination with, for example, tampering alarms, motion detection, event triggering, time lapse recording and alarm notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:

Digital output – For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The output will show as active (shown under System Options > Ports & Devices) if the alarm device is activated.

Digital input – An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under System Options > Ports & Devices).

SD Card Slot

A microSD card (not included) can be used for local recording with removable storage. For more information, see Technical Specifications on page 62.

NOTICE

Risk of damage to SD card. Do not use sharp tools or excessive force when inserting or removing the SD card.

Risk of data loss. To prevent corruption of recordings, the SD card should be unmounted before removal. To unmount, go to Setup > System Options > Storage > SD Card and click Unmount.

Note

For SD card recommendations see www.axis.com

Control Button

For location of the control button, see Hardware Overview on page 6 .

The control button is used for:

Resetting the product to factory default settings. See page 57.

Connecting to an AXIS Video Hosting System service. See page 50. To connect, press and hold the button for about 3 seconds until the Status LED flashes green.

Connecting to AXIS Internet Dynamic DNS Service. See page 50. To connect, press and hold the button for about 3 seconds.

LED Indicators

Note

The Status LED can be configured to flash while an event is active.

The Status LED can be configured to flash for identifying the unit. Go to Setup > System Options > Maintenance .

Status LED

Indication

 

 

Unlit

Connection and normal operation.

 

 

Green

Shows steady green for 10 seconds for normal operation after startup completed.

 

 

Amber

Steady during startup. Flashes during firmware upgrade.

 

 