Axis Communications M5013 user manual Audio detection

Models: M5013

1 50
Download 50 pages 35.06 Kb
Page 24
Image 24

AXIS M5013 PTZ Dome Network Camera

Detectors

Parameter

Object Size

History

Sensitivity

 

 

 

 

Description

Object size relative to window

Object memory length.

Difference in luminance

 

size.

 

between background and

 

 

 

object.

 

 

 

 

High level (100%)

Only very large objects trigger

An object that appears in

Ordinary colored objects on

 

motion detection.

the window triggers motion

ordinary backgrounds trigger

 

 

detection for a long time

motion detection.

 

 

before it is considered as

 

 

 

non-moving.

 

 

 

 

 

Medium level (50%)

 

 

A large difference in luminance

 

 

 

is required to trigger motion

 

 

 

detection.

 

 

 

 

Low level (0%)

Even very small objects trigger

An object that appears in

Only very bright objects on

 

motion detection.

the window triggers motion

a dark background trigger

 

 

detection only for a very short

motion detection.

 

 

time before it is considered as

 

 

 

non-moving.

 

 

 

 

 

Recommended values

5–15%

60–90%

75–95%

 

 

 

 

Default values

15%

90%

90%

 

 

 

 

Tips:

 

 

 

To trigger on small objects or movements, use several small motion detection windows rather than one large window and select a low object size.

To avoid triggering on small objects, select a high object size.

If no objects should appear in the Include Window, select a high history level. This will cause motion detection to trigger as long as the object is present in the window.

To only detect flashing light, select a low sensitivity. In other cases high sensitivity is recommended.

Audio detection

The Axis product can be configured to generate an alarm when audio rises above or falls below the threshold value. The threshold value can be set in the range 0–100 where 0 is the most sensitive and 100 the least sensitive.

1.Go to Detectors > Audio Detection.

2.Set the audio alarm level and click Save.

3.Go to Events > Action Rules and set up an action rule, see Setting Up an Action Rule, on page 27.

Note

Audio alarm is disabled by default during PTZ movement. To enable, clear the Alarm automatically disabled during PTZ movement check box option.

Detected audio is indicated by colored peaks in the Activity indicator. An event is triggered when detected audio rises above or falls below the threshold value, which is represented by the bar.