Unit connectors

Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet (PoE) Class 3 - max 12.95W. Using shielded cables is recommended.

Power input connector - 2-pin terminal block used for power input from the supplied power adapter or an external power supply.

The external power supply alternatives are:

1.

The Axis delivered PS-K P/N 34987 (AXIS M7014).

 

 

 

 

1

2

2.

The Axis delivered PS-P P/N 42118 (AXIS M7010).

 

 

 

 

3.

An external 8-20 V DC limited power source with a maximum output current of 5A.

 

 

 

 

 

 

 

 

 

 

 

Function

Pin number

Description

 

 

 

 

 

 

 

 

 

 

 

GND

1

Ground

 

 

 

 

 

 

 

 

 

 

 

DC Power

2

Power input 8-20V DC

 

 

 

 

 

 

 

max 7W (AXIS M7014)

 

 

 

 

 

 

 

max 28W (AXIS M7010)

 

 

 

 

 

 

 

 

 

 

 

 

RS-485/RS-422 connector - Two 2-pin terminal blocks for RS-485/RS-422 serial interface used to control auxiliary equipment, e.g. PTZ devices.

The RS-485/RS-422 serial port can be configured to support:

 

RS-485/422

 

 

 

 

 

 

 

 

 

 

 

 

 

Two-wire RS-485 half duplex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Four-wire RS-485 full duplex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Two-wire RS-422 simplex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Four-wire RS-422 full duplex point to point communication

RX/TX

 

 

TX

 

 

 

 

1

 

 

2

 

 

3

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

Pin

Notes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-485/RS-422 RX/TX A

1

(RX) For full duplex RS-485/RS-422

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(RX/TX) For half duplex RS-485

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-485/RS-422

RX/TX B

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-485/RS-422

TX A

3

(TX) For full duplex RS-485/RS-422

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-485/RS-422

TX B

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

microSD memory card slot - The microSD memory card can be used for local recording with removable storage.

BNC connector - Connect a 75 ohm coaxial video cable (max. length 800 feet (250 meters)).

Note: For each video input 75 Ohm video termination can be enabled/disabled via the product's web page at Video > Video Input > Video termination. These terminations are enabled on factory default. In cases