AXIS Q6034 PTZ Dome Network Camera

Technical Specifications

Function

Pin

Notes

Specifications

 

 

 

 

GND

1

Ground

 

 

 

 

 

3.3 V DC Power

2

Can be used to power auxiliary equipment.

Max load = 250 mA

 

 

Note: This pin can only be used as power out.

 

 

 

 

 

Configurable

3–6

Digital input — Connect to GND to activate, or leave floating

0 to +40 V DC

(Input or Output)

 

(unconnected) to deactivate.

 

 

 

Digital output — Internal connection to ground when

Max load =100 mA

 

 

activated, floating (unconnected) when deactivated. If used

Max voltage = +40 V DC

 

 

with an external relay, a diode must be connected in parallel

 

 

 

with the load, for protection against voltage transients.

 

 

 

 

 