AXIS Q6044-C PTZ Dome Network Camera
Multi-Connector Cable
The supplied
The
• DC power to camera
• Network (Ethernet
• Input/Output (I/O)
Function | Pin – wire | Notes | Specifications | |
|
|
|
| |
Configurable (Input | 2 – blue | Digital input – Connect to pin 8 to activate, or | 0 to max 30 V DC | |
or Output) | 7 | – yellow | leave floating (unconnected) to deactivate. |
|
|
|
|
|
|
|
|
| Digital output – Connected to pin 1 when | 0 to max 30 V DC, open |
|
|
| activated, floating (unconnected) when | drain, 100 mA |
|
|
| deactivated. If used with an inductive load, e.g. a |
|
|
|
| relay, a diode must be connected in parallel with |
|
|
|
| the load, for protection against voltage transients. |
|
|
|
|
|
|
RX+ | 3 | – green/white | Ethernet – receiving |
|
|
|
|
|
|
RX- | 4 | – green | Ethernet – receiving |
|
|
|
|
|
|
TX+ | 5 | – orange/white | Ethernet – transmitting |
|
|
|
|
|
|
TX- | 6 | – orange | Ethernet – transmitting |
|
|
|
|
|
|
0 V DC | 8 | – black |
| 0 V DC |
|
|
|
| |
DC output (12 V) | 1, 9 – red | Used to power camera | ||
|
|
|
| Max load = 6 A |
|
|
|
|
|
57