Axis Communications Q6044-C user manual Performance Considerations, Power connector DC output

Models: Q6044-C

1 67
Download 67 pages 21.72 Kb
Page 65
Image 65

AXIS Q6044-C PTZ Dome Network Camera

Technical Specifications

Power connector (DC output)

Two 2-pin terminal blocks for power output (pin 4 is not used).

Function

 

Pin

Notes

Specifications

 

 

 

 

 

DC output

12 V DC

1, 2

Power out to camera

Max load = 6.5 A

 

 

 

 

12.0–13.2 V DC, min 70 W

 

 

 

 

 

 

GND

3

Ground

 

 

 

 

 

 

 

N/a

4

N/a

 

 

 

 

 

 

Network connector (internal)

Two 2-pin Ethernet terminal blocks.

I/O terminal connector (external)

6-pin terminal blocks for:

Digital Input/Output

 

 

 

Power (DC output)

 

 

 

Ground (GND)

 

 

 

 

 

 

 

 

Function

 

Pin

Notes

Specifications

 

 

 

 

 

GND

 

1, 4, 6

Ground

 

 

 

 

 

 

DC output

 

2

Power out

12 V DC, 50 mA

 

 

 

 

Configurable I/O 1 (Input or

3

Digital input

0 to +30 V DC

Output)

 

 

 

 

 

 

Digital output (transistor – open

Max load = 100 mA

 

 

 

 

 

 

collector)

Max voltage = +30 V DC

 

 

 

 

Configurable I/O 2 (Input or

5

Digital input

0 to +30 V DC

Output)

 

 

 

 

 

 

Digital output (transistor – open

Max load = 100 mA

 

 

 

 

 

 

collector)

Max voltage = +30 V DC

 

 

 

 

 

I/O terminal connector (internal)

2-pin terminal block.

Performance Considerations

When settings up your system, it is important to consider how various settings and situations will affect performance. Some factors affect the amount of bandwidth (the bit rate) required, others can affect the frame rate, and some affect both. If the load on the CPU reaches its maximum, this will also affect the frame rate.

65

Page 65
Image 65
Axis Communications Q6044-C user manual Performance Considerations, Power connector DC output, Network connector internal