English

ThermoBalance II Rough 06623000

ThermoBalance II Rough with Stops 06627000

The cartridge shown is included with the trim kit.

The Service (Isolation) Stops

screwdriver slots

(For the sake of clarity, the plastic installation box (i-box) is not shown in these illustrations. The i-box should not be removed.)

Rough-in 06627000 has service (isolation) stops built onto the valve. When the screw- driver slots is horizontal, the stops are in the “on” position. When the screwdriver slots are vertical, the stops are in the “off” position.

When connecting the hot and cold supplies, hold the stop steady with a wrench to avoid stop mis-alignment, and breakage of the fac- tory sealed thread compound.

Technical Specifications

Recommended pressure

45 - 72 psi

Maximum hot water temperature

165° F*

Recommended hot water temp.

120° - 140° F*

Nominal capacity @ 45 psi

8 gpm

Nominal capacity @ 60 psi

11.5 gpm

Safety stop

100° F

Maximum output temperature

110° F**

½” NPT connections

 

*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. **The high temperature limit stop may be reset to comply with local plumbing codes. See page 11.

Page 2
Image 2
Axor 06064XX0 installation instructions English, Service Isolation Stops, Technical Specifications