Install the carrier plate gasket and carrier plate with the carrier plate screws.
Press the escutcheon very firmly over the carrier plate, so that the strips of Duotec interlock, produc- ing a very firm hold.
Install the handle: Tighten the handle screw, using a 3 mm Allen wrench. For proper operation of the valve, the handle screw must engage the slot milled into the brass on the cartridge.
Set the high temperature limit stop (optional)
Justify the handle.
English |
Justify the Handle
Tools required: Thermometer
3 mm Allen wrench (included with trim kit)
Turn the valve on. Place the thermometer in the water stream.
Turn the temperature control knob until the water coming out measures 100° on the thermometer.
Turn the water off using the lever part of the handle.
Use the 3 mm Allen wrench to loosen the set screw on the bottom of the handle. Remove the handle from the valve (1).
Hold the lever in one hand. With the other hand, turn the temperature control knob approximately
½turn clockwise (2a). Then, without pressing inward on it, turn it
Reinstall the handle and tighten the set screw (3).
2
ab