6 2010AS3297 Manual
B&BElectronics -- PO Box 1040 -- Ottawa, IL 61350
PH(815) 433-5100 -- FAX (815) 434-7094
4.0 INSTALLATION
TheModel 2010 is designed to be used in
pairs
,with one unitinstalled
betweenan asynchronous DTE and a synchronous DCE on either end of a
synchronouscommunication link. Figure 4 (below) illustrates a typical
Model 2010 installation.
Figure4. TypicalModel 2010 application
4.1 CONNECTING THE ASYNCHRONOUS PORT
Theasynchronous port of the Model 2010 is a DB-25 female and is
configuredas "DCE". Therefore, it wants to talk to a DTE device such as a
terminal orPC. The Model 2010 may be plugged directly into the DB-25
serial port of a DTE or connected via "straight through" cable.
4.2 CONNECTING THE SYNCHRONOUS PORT
Thesynchronous port of the Model 2010 is a DB-25 male and is
configuredas "DTE." Therefore, it wants to talk to a DCE device such as a
modemor multiplexer. The Model 2010 may be plugged directly into the
DB-25serial port of a DCE or connected via "straight through" cable.