4.0 INSTALLATION

The Model 2010 is designed to be used in pairs, with one unit installed between an asynchronous DTE and a synchronous DCE on either end of a synchronous communication link. Figure 4 (below) illustrates a typical Model 2010 installation.

Figure 4. Typical Model 2010 application

4.1 CONNECTING THE ASYNCHRONOUS PORT

The asynchronous port of the Model 2010 is a DB-25 female and is configured as "DCE". Therefore, it wants to talk to a DTE device such as a terminal or PC. The Model 2010 may be plugged directly into the DB-25 serial port of a DTE or connected via "straight through" cable.

4.2 CONNECTING THE SYNCHRONOUS PORT

The synchronous port of the Model 2010 is a DB-25 male and is configured as "DTE." Therefore, it wants to talk to a DCE device such as a modem or multiplexer. The Model 2010 may be plugged directly into the DB-25 serial port of a DCE or connected via "straight through" cable.

6

2010AS3297 Manual

B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 434-7094

Page 8
Image 8
B&B Electronics 2010 manual Installation, Connecting the Asynchronous Port, Connecting the Synchronous Port