Table 1. Communication & Configuration Switch

Table 1. Communication & Configuration Switch

 

 

DIP Switch 1

 

 

 

1

2

3

4

5

6

7

8

Setting

0

0

0

 

0

X

X

X

X

300 Baud

1

0

0

 

0

X

X

X

X

600 Baud

0

1

0

 

0

X

X

X

X

1200 Baud

1

1

0

 

0

X

X

X

X

2400 Baud

0

0

1

 

0

X

X

X

X

4800 Baud

1

0

1

 

0

X

X

X

X

9600 Baud *

0

1

1

 

0

X

X

X

X

19.2K Baud

1

1

1

 

0

X

X

X

X

38.4K Baud

X

X

X

 

X

0

X

X

X

8 Data Bits *

X

X

X

 

X

1

X

X

X

7 Data Bits

X

X

X

 

X

X

0

X

X

Smart Switch Mode *

X

X

X

 

X

X

1

X

X

Smart Switch and

 

 

 

 

 

 

 

 

 

Port Combiner Mode

X

X

X

 

X

X

X

0

X

3 Char. Command *

X

X

X

 

X

X

X

1

X

4 Char. Command

X

X

X

 

X

X

X

X

0

Port Select Test Off *

X

X

X

 

X

X

X

X

1

Port Select Test On

 

 

0

= OFF

1 = ON

X = DON'T CARE

 

 

 

 

 

* = FACTORY DEFAULT

Port Configuration

The 232D4SS8 has a Master port and eight selectable ports labeled "A" through "H". Refer to “Rear View”. The Master port should be connected to the RS-232 device that will be selecting the ports. Ports "A - H” connect to the RS-232 or RS-422/485 devices that will communicate with the Master port device.

Master Port

The Master port can be configured by the user as a DCE or a DTE port. In order to determine the proper Master port configuration of the 232D4SS8 it is necessary to have a basic understanding of the terms DCE and DTE. RS-232 was designed, using DB-25 connectors, for connecting a DTE (Data Terminal Equipment) device to a DCE (Data Communication Equipment) device. Each device will have inputs on pins that correspond to outputs on the same pins of the other device. For example, a DTE device transmits data out on pin 2 and a DCE device receives data in on pin 2. IBM PC's are DTE devices, modems are DCE devices. The Master port is shipped configured as a DCE port.