Table D-1 Extended Commands
Function
Read I/O Lines
Set Output Lines
Set Module
Address
Set
Define I/O Lines
Set
Read Configuration
Command | Response |
|
|
#{addr}RD | {I/O msb}{~I/O msb}{I/O |
| lsb}{~I/O lsb} |
#{addr}SO{I/O | no response |
msb}{~I/O msb}{I/O |
|
lsb}{~I/O lsb} |
|
#{addr}SA{new | no response |
addr}{~new addr} |
|
#{addr}SC{x}{~x} | no response |
|
|
#{addr}SD{I/O | no response |
msb}{~I/O msb}{I/O |
|
msb}{~I/O msb} |
|
#{addr}SS{I/O | no response |
msb}{~I/O msb}{I/O |
|
lsb}{~I/O lsb} |
|
#{addr}RC | {I/O msb}{~I/O msb}{I/O |
| lsb}{~I/O lsb}{I/O powerup |
| msb states}{~I/O powerup |
| msb states}{I/O powerup |
| lsb states}{~I/O powerup |
| lsb states}{addr}{~addr}{turn- |
| around |
| delay} |
|
|
Where “x” is the required data byte and “~” signifies the complement of the specified byte.