B&B Electronics P#8506R2 quick start Verifying Installation, Dip Switch Setting, Pinouts

Models: P#8506R2

1 2
Download 2 pages 63.36 Kb
Page 2
Image 2
Verifying Installation

4

Verifying Installation

1.To verify the installation went correctly open the Windows Device Manager

Scroll down to Ports,

Expand the ports by clicking on the plus sign (+), this shows if the ports now exist on the PC.

If there are no exclamation points or other indicators of a problem the ports should be installed correctly and ready for use.

2.Verifying with a loopback test.

If the device is RS-232, loopback pins 2 and 3. If the device is RS-422 or RS-485, loopback the TDA(-) to RDA(-) and TDB(+) to RDB(+). Use the pin-out charts for the location of each pin or terminal.

Using Hyper Terminal or similar program, connect to the appropriate COM port. Set the desired baud rate. Ensure Hyper Terminal local echo is OFF. (Note:

Hyper Terminal is not provided with Vista or 2003 Server)

Transmit data. If the same character string is returned, the test is good.

5

Dip Switch Setting

Note: For models with selectable RS-422/485 configurations

Dip switches allow the module to be configured for two-wire or four-wire, RS-422 or RS-485 modes. In two-wire mode the TDA (-) and RDA (-) are tied together and so are TDB (+) and RDB (+), making multi-dropping this converter into an existing network easy.

Dip Sw itch Settings

Sw itch

Off (left)

On (right)

1

RS-422

RS-485

2

ECHO ON

ECHO OFF

3

4-Wire

2-Wire

4

4-WIre

2-Wire

6 Pinouts

P#8506R2 ULINX 1&2 PORT_0712qsg

DB9 Female

RS-485 Pinout (DB9 Female)

Pin

RS-485, 4 Wire

RS-485, 2 Wire

1

Not Used

Not Used

2

Receive RDA (-) Input

Data A (-) Input / Output

3

Transmit TDB (+) Output

Data B (+) Input / Output

4

Ground

Ground

5

Not Used

Not Used

6

Ground

Ground

7

Receive RDB (+) Input

Data B (+) Input / Output

8

Transmit TDA (-) Output

Data A (-) Input / Output

9

Not Used

Not Used

DB9 Male

RS-232 and TTL Pinout (DB9 Male DTE)

TO PC

RS-232

TDA(-) Hyper Terminal is not provided with Vista or 2003 Server) USB TDB(-) Dip Switch SettingNote: For models with selectable RS-422/485 configurations6 Pinouts RDA(-) Manual backgroundManual background

RDB(-) Manual backgroundManual background

GND

RS-485

RS485 Pinout (Terminal Blocks)

Terminal

 

 

Position

RS-485, 4 Wire

RS-485, 2 Wire

A

Transmit TDA (-) Output

Data A (-) Input / Output

B

Transmit TDB (+) Output

Data B (+) Input / Output

C

Receive RDA (-) Input

Data A (-) Input / Output

D

Recieve RDB (+) Input

Data B (+) Input / Output

E

Ground

Ground

 

 

RS-232

TTL

PIN

Signal Name

Signals

Signals

1

DCD (Data Carrier Detect)

Input

Not Used

2

RD (Receive Data)

Input

Input

3

TD (Transmit Data)

Output

Output

4

DTR (DTE Ready)

Output

Not Used

5

SG (Signal Ground)

Ground

Ground

6

DSR (DCE Ready)

Input

Not Used

7

RTS (Request to Send)

Output

Output

8

CTS (Clear to Send)

Input

Input

9

RI (Ring Indicator)

Input

Not Used

NOTE: To remove drivers from a PC, there is an Uninstall reference document on the CD ROM.

Page 2
Image 2
B&B Electronics P#8506R2 quick start Verifying Installation, Dip Switch Setting, Pinouts