DANGER:Tefollowingworkistobeperformedonlybyalicensedelectrician.

ishazardous

 

 

TROUBLESHOOTING

 

 

voltagewhichcanshock,burnorkill.Turnpoweroff.UnplugpowercordbeforeservicorTherecleaning.

 

!

!

 

 

 

 

 

 

 

 

 

 

Problem:

Probable Cause:

Solution:

 

 

 

 

 

 

 

Unit will not run (heater

Power cord is not plugged in

Plug in power cord

 

 

and fan are off)

 

 

 

 

 

 

 

 

 

Circuit breaker is tripped

Call a licensed electrician

 

 

 

 

 

 

No power at outlet

Call a licensed electrician

 

 

 

 

 

 

Defective power cord or switch

Call a licensed service agency or a

 

 

 

licensed electrician

 

 

 

 

 

 

Compartment too cold

Check door

Instruct user to keep door closed

 

 

 

 

 

Poor door seal

Check door seal and replace if necessary

 

 

 

 

 

Thermostat setting is too low

Turn thermostat knob to a warmer

 

 

 

position. This should be done one

 

 

 

increment at a time until a satisfactory

 

 

 

temperature is obtained

 

 

 

 

 

 

Defective thermostat

Check thermostat. If necessary, call a

 

 

 

licensed service agency or a licensed

 

 

 

electrician

 

 

 

 

 

Compartment too hot

Thermostat setting is too high

Turn thermostat knob to a cooler position.

 

 

This should be done one increment at a

 

 

time until a satisfactory temperature is

 

 

 

obtained

 

 

 

 

 

 

 

Defective thermostat

Check thermostat. If necessary, call a

 

 

 

licensed service agency or a licensed

 

 

 

electrician

 

 

 

 

 

 

 

No humidity

No water in pan

Add hot water

 

 

 

 

 

 

 

 

Selector Switch on heat

Switch to Proof Mode

 

 

 

 

 

 

Humidity thermostat set too low

Adjust thermostat (usually 1/4 to 1/3 of full

 

 

range)

 

 

 

 

 

 

 