Installation
Serious injury, equipment damage or death could result if attempting to install this unit yourself. Ensure that an authorized BKI service agent install the oven.
Instructions For Shipping Damage
You are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates for damage when they arrive. If there is damage noted to shipping crates or cartons, or, if a shortage is found, note this on the bill of lading (all copies) before signing.
If damage is detected when the equipment is uncrated, immediately call the delivering truck line and follow up the call with a written report indicating concealed damage to your equipment. Ask for an immediate inspection of your concealed damage item. Crating material MUST be retained to show the inspector from the truck line.
Electrical Information And Grounding
Electrocution, equipment failure or property damage could result if an unlicensed electrician performs the electrical installation. Ensure that a licensed electrician perform the electrical installation in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI NFPA
The
BKI Fry Warmers are wired for use in accordance with all applicable local, state, and federal codes. For specific electrical requirements and connections refer to the wiring diagram attached to the unit or provided in the Service Manual.
Installation Instructions
If a side or back panel is removed on the chute, the other two sides must be sealed with NSF approved silicone. Seal all inside seams greater than 1/32”.
FW-12 & FW-12T (Side Breather)
Countertop Adapter
1.Obtain a suitable countertop location for the unit that will provide a clearance of 4” from the side louvers.
2.Position the adapter (WN31206400) on the countertop.
3.Using a 1/8” drill bit, drill holes in the countertop used to secure the adapter to the countertop.
4.Using a 2” hole saw, drill a hole in the countertop (directly under the hole in the adapter) used for the power cord to pass through.
5.Secure adapter to countertop with # 8 sheet metal screws.
6.Seal adapter to the countertop to conform to NSF Standard 4, Item 4.28. (Dow Corning RTV #732 Multi purpose Sealant.)
7.Feed power cord (supplied), up through holes in countertop and adapter.