Appendix A

Appendix A

PG6000 Connections

Caution: The brass connecting tab on some 120VAC duplex receptacles has been removed. Each receptacle is powered by a separate generator winding. When replacing a receptacle, inspect the brass tab that normally links both receptacles. If it is removed, be sure to remove the brass tab from the replacement receptacle before it is installed. Failure to remove the tab will cause a direct short to the generator windings and cause possible generator damage.

Wiring Diagrams Wiring diagrams for these generators are contained on the following pages of this appendix.

MN2418

PowerchiefR Series A-1

Page 21