WALL MOUNT GENERAL INFORMATION
AIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE
MODEL NUMBER |
|
|
|
| CONTROL MODULES |
| WL 70 1 – B 09 X | X X X X J | J - Standard on all | ||
CAPACITY | Models | ||||
|
|
|
|
| |
70 - 6 Ton |
|
|
| COIL OPTIONS | |
|
|
|
| ||
|
|
|
| X - Standard | |
REVISION |
| VENTILATION OPTIONS |
| 1 - Phenolic Coated Evaporator | |
|
| X - Barometric Fresh Air Damper |
| 2 - Phenolic Coated Condenser | |
VOLTS & PHASE |
| (Standard) |
| 3 - Phenolic Coated Evaporator | |
A - | KW | B - | COLOR OPTIONS | and Condenser | |
|
|
| |||
B - | M - Motorized Fresh Air Damper |
| |||
C - | 0Z - No KW | V - Commercial Room Ventilator - | X - Beige |
|
|
| Motorized with Exhaust | (Standard) |
|
| |
| w/Circuit Breaker | OUTLET OPTIONS | |||
| E - Economizer (Internal) - Fully | 1 - White | |||
| or Pull | X - Front (Standard) | |||
| Modulating with Exhaust |
| |||
| Disconnect |
|
|
| |
| R - Energy Recovery Ventilator - |
|
|
| |
| 05 - 5 KW |
|
|
| |
| with Exhaust | FILTER OPTIONS |
|
| |
| 09 - 9 KW |
|
| ||
| 10 - 10 KW |
| X - One Inch Throwaway |
| |
| 15 - 15 KW |
| (Standard) |
|
|
| 18 - 18 KW |
| W - One Inch Washable |
|
|
|
|
| P - Two Inch Pleated |
|
|
NOTE: For 0KW and circuit breakers (230/208 V) or pull disconnects (460 V) applications, insert 0Z in the KW field of model number.
TABLE 1
ELECTRICAL SPECIFICATIONS
Single Circuit | Dual Circuit |
|
|
| 3 | 1 | 2 | 2 |
| 3 |
| 1 |
| 2 | 2 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Field Wire | Ground | |||
|
| No. of |
|
| Field | Ground |
| MCA | MOP | Size | Wire Size | ||||||
|
|
|
| Wire | Wire |
|
|
|
|
|
|
|
|
|
|
| |
|
| Power |
|
| CKT | CKT | CKT |
| CKT | CKT |
| CKT | CKT | CKT | |||
|
| MCA | MOP | Size | Size |
|
| ||||||||||
Models | Rated | Circuits | A |
| B | A |
| B | A |
| B | A | B | ||||
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | 48 | 60 | 8 | 10 | NA |
| NA | NA |
| NA | NA |
| NA | NA | NA | ||
1 | 48 | 60 | 8 | 10 | NA |
| NA | NA |
| NA | NA |
| NA | NA | NA | ||
1 | 59 | 60 | 6 | 10 | NA |
| NA | NA |
| NA | NA |
| NA | NA | NA | ||
1 or 2 | 85 | 90 | 4 | 8 | 59 |
| 26 | 60 |
| 30 | 6 |
| 10 | 10 | 10 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | 36 | 50 | 8 | 10 | NA |
| NA | NA |
| NA | NA |
| NA | NA | NA | |
1 | 36 | 50 | 8 | 10 | NA |
| NA | NA |
| NA | NA |
| NA | NA | NA | ||
1 | 52 | 60 | 6 | 10 | NA |
| NA | NA |
| NA | NA |
| NA | NA | NA | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | 17 | 25 | 12 | 12 | NA |
| NA | NA |
| NA | NA |
| NA | NA | NA | |
1 | 17 | 25 | 12 | 12 | NA |
| NA | NA |
| NA | NA |
| NA | NA | NA | ||
| 1 | 26 | 30 | 10 | 10 | NA |
| NA | NA |
| NA | NA |
| NA | NA | NA | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
jMaximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.
kBased on 75°C copper wire. All wiring must conform to the National Electric Code (NEC) and all local codes.