Baxi Potterton 105 HE, 80 HE manual Operating the Boiler, Reset

Models: 80 HE 105 HE

1 12
Download 12 pages 23.05 Kb
Page 6
Image 6

6

7

8

9

10

11

30o

40o

50o

60o

70o

80o

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Power On

 

 

1

3

Neon

 

Burner On

 

 

 

Neon

 

 

 

 

0

4

 

 

 

Fig. 5

 

 

 

bar

Domestic

 

 

 

 

Central

 

 

 

Hot Water

 

 

 

Neon

Heating Neon

Fig. 4

Central Heating System

 

 

 

Pressure Gauge

 

 

 

 

 

 

 

PREHEAT

 

 

30o 40o 50o 60o 70o 80o

OFF

 

 

 

 

 

2

Reset

 

ON

1

3

 

 

 

0

4

 

 

 

 

bar

On/Off/Reset

Selector Switch

3.0 Operating the Boiler

3.1Operating the Boiler

1.Ensure that the electricity and gas supplies are turned on. Check that the central heating pressure is between 0.5 and 1.0 bar (Fig. 4).

2.Turn the On/Off/Reset selector switch either anti- clockwise from the off position (Fig. 6) to both central heating and domestic hot water or clockwise to domestic hot water only.

3.In either position the green power on indicator

( ) will illuminate (Fig. 5).

4.Position (i) In this position the central heating will operate according to demand or provide domestic hot water when a tap or shower is turned on (Fig. 7). Priority

is given to domestic hot water. The central heating/hot water neon ( ) will illuminate (Fig. 5). Neons 6 to 11 will illuminate as the temperature rises.

5.Position (ii) In this position hot water will be provided

when a tap or shower is turned on

(Fig. 8). The hot water neon ( ) will illuminate (Fig. 5).

6.The boiler will light automatically on demand.

7.The orange burner on neon ( ) will illuminate when the boiler is operating and the main burner is on (Fig. 5).

IMPORTANT: When the selector switch is in the ‘0’ (Off) position the electrical supply to the boiler is isolated. The boiler will not operate and the integral timer (if fitted) will require resetting once the selector switch is set to either Position (i) or Position (ii).